A heat pump can heat a house, prepare domestic hot water, and in the right configuration, also cool rooms in summer. It does not burn gas, coal or pellets in the building. Instead of generating all the heat it needs from electricity, it takes it from the environment – air, ground or water – and transfers it to the heating system.

However, this does not mean that a heat pump will be an equally good solution in every home. Its energy consumption and operating costs depend, among other things, on the building's heat demand, its insulation, the type of heating system, the supply temperature and the correct selection of the device's power.

In this guide, we explain how a heat pump works, how different its types are, how much it can cost to buy and heat a home in 2026, and what you need to check before making a decision.

What is a heat pump?

A heat pump is an electric heating device that transports heat energy from a place with a lower temperature to the heating system of the building.

The source of this energy – called the bottom source – can be:

  • outdoor air,
  • land,
  • water.

The heat then goes to the so-called upper source, i.e. the installation in the building: underfloor heating, radiators, hot water system or supply system.

The pump needs electricity to work, primarily to drive the compressor, circulation pumps and automation. However, this does not mean that 1 kWh of electricity consumed gives only 1 kWh of heat.

For example, a COP of 4 means that under certain conditions the device provides about 4 kWh of thermal energy using 1 kWh of electricity.

And this is where the most important difference between a heat pump and ordinary electric resistance heating lies.

How does a heat pump work?

The principle of operation may seem complicated, but it can be reduced to a single process: the device collects heat from the environment, raises its temperature and transfers it to the building.

There is a working medium in the closed circuit of the pump. Passing through the evaporator, compressor, condenser, and expansion valve in turn, it changes the temperature, pressure, and state of matter.

1. Heat intake

In an evaporator, the working medium receives energy from the air, ground or water. Even if the temperature outside is freezing, the air still contains heat energy that can be used by a properly designed pump.

2. Prestressing

The refrigerant in gaseous form goes to the compressor. An increase in pressure causes its temperature to rise at the same time.

It is at this stage that the largest part of the electricity needed by the pump is consumed.

3. Heat Release

The hot medium goes to the condenser and transfers energy to the water in the heating system.

The heat can then go to:

  • underfloor heating,
  • radiators,
  • domestic hot water tank.

4. Expansion

After the energy is released, the medium passes through an expansion valve. Its pressure and temperature drop, so it can reabsorb heat from the environment.

The cycle starts from the beginning.

What are the types of heat pumps?

The basic division results from the type of lower source: air, ground or water. In the case of the most popular air-to-water pumps, there is also a distinction between split and monoblock designs.

Therefore, from the point of view of the homeowner, it is worth comparing the five most common solutions:

TypeWhere does it get its heat from?Where does it give off heat?Key features
Air-water splitAirWater systemOutdoor and indoor unit connected by a working medium installation
Air-to-water monoblockAirWater systemRefrigerant circuit closed at the factory in one unit
Ground brine-waterGroundWater systemStable bottom source, requires horizontal collector or probes
Water-to-waterGroundwaterWater systemHigh efficiency, but higher requirements for local conditions
Air-to-airAirAir in the buildingSupply heating, structurally similar to air conditioning with heating function

Split air-to-water heat pump

The system consists of two units. The part installed outside takes heat from the air, while the indoor unit transfers it to the heating system.

Both parts are connected by pipes in which the refrigerant circulates. For this reason, the installation requires appropriate qualifications related to refrigeration systems.

Split gives a lot of flexibility when choosing the installation location and is used in both new and retrofit buildings.

Monoblock air-to-water heat pump

In a monoblock, the entire main cooling circuit is factory-sealed in one housing. Water pipes are routed to the building.

The solution simplifies some of the installation work, but requires proper protection of the water system against freezing in the event of a prolonged standstill of the device or power failure.

At the same time, it cannot be said that a monoblock is by definition more efficient than a split. The structural division alone does not give a major advantage in terms of annual efficiency – the specific model, selection and operating conditions are more important.

Ground source heat pump

The bottom source is the ground, the temperature of which is much more stable than the air temperature during the heating season.

Energy can be drawn through a horizontal collector or vertical ground probes.

The advantage is high and stable efficiency. The disadvantage is the higher cost of the investment and the need to build a bottom source. The Polish Geological Institute indicates that ground source heat pumps are among the solutions that achieve high efficiency factors.

Water-to-water heat pump

In this case, energy is taken from water, most often groundwater, using a properly prepared well system.

Hydrogeological conditions must allow such a solution to be used. For this reason, it is not as versatile as an air pump.

Air-to-air heat pump

There is no water central heating system here. The heat taken from the outside air is transferred directly to the room heating air.

This group includes, among others, systems that work similarly to air conditioners with a heating function.

Such a device may work well in certain buildings, but it does not automatically replace the domestic hot water preparation system.

COP and SCOP – what does electricity consumption depend on?

When comparing heat pumps, it is easy to come across COP values exceeding 4 or even 5. However, you need to know what exactly they mean.

The COP shows the effectiveness of the device under specific measurement conditions.

If the COP is 4:

1 kWh of electricity → about 4 kWh of heat.

The problem is that the conditions change throughout the season.

The efficiency at +7°C outside will be different during frost. It also makes a difference whether the pump heats water up to 35°C for underfloor heating or has to supply, for example, 50-55°C to the radiator system.

Therefore, when estimating annual costs, SCOP – the seasonal efficiency factor – is more important.

For example:

If the house needs 12,000 kWh of heat per year and the system reaches SCOP = 4 seasonally:

12,000 kWh ÷ 4 = about 3000 kWh of electricity.

That is why it is impossible to answer the question "how much electricity does a heat pump consume?" without information about the building itself.

How much does a heat pump cost in 2026?

The price of the device itself is only part of the investment.

The cost estimate may also include:

  • installation,
  • hot water tank,
  • buffer,
  • fittings,
  • modernization of the heating system,
  • modernization of the electrical installation,
  • making the bottom source,
  • boreholes,
  • design and commissioning.

The cost of the device itself, which can be found in the catalog, is one thing. The real approximate values of the complete investment (with assembly, additional devices necessary to connect to the existing installation, storage tanks, etc.) are in the following ranges:

System TypeApproximate investment cost
Air-waterapprox. PLN 60,000–92,000
Water-to-waterapprox. PLN 80,000–108,000
Ground – horizontal collectorapprox. PLN 76,000–96,000
Ground – vertical collectorapprox. PLN 100,000–120,000

These are indicative ranges. The actual cost depends on the device, installation, site preparation and the scope of additional work.

In a particular house, the cost can therefore be both below and above these values.

There is a particularly big difference between a new building, in which the installation was designed for a heat pump from the beginning, and the modernization of an older house, which requires the reconstruction of the heating system.

How much does heat pump heating cost?

The most important thing is not the size of the house, but its annual demand for thermal energy.

Let's take three purely model examples:

Annual heat demandSCOP adoptedEnergy consumption of the pump
12,000 kWh4,0approx. 3000 kWh
18,000 kWh3,5approx. 5140 kWh
25,000 kWh3,0approx. 8330 kWh

In 2026, the average selling price of electricity for households approved by the President of the Energy Regulatory Office is PLN 495.16/MWh net. However, the sale price is supplemented by distribution and other fees.

For example, in the Enea area in the G11 tariff, energy currently costs PLN 0.6187/kWh gross, while the variable distribution component is PLN 0.3021/kWh. It is supplemented, m.in, by quality, RES and cogeneration fees. This gives about PLN 0.97 of variable costs per additional kWh, even before the distribution of fixed fees for consumption.

With such a purely model assumption:

  • 3000 kWh is about PLN 2900 per year of variable costs,
  • 5140 kWh – about 5000 PLN,
  • 8330 kWh – about 8100 PLN.

These are not bill forecasts for a specific house. However, they show an important relationship: the cost of heating is primarily determined by the building's heat demand and the achieved SCOP.

Fixed fees are also added to the farm's bill. In 2026, a household consuming more than 2800 kWh per year pays, for example, PLN 24.05 per month in capacity fee.

Heat pump and photovoltaics

Part of the pump's consumption can be covered by the energy produced by your own PV system.

The biggest challenge comes from seasonality: photovoltaics produce the most in summer, while the pump consumes the most energy in winter.

However, this does not mean that the two solutions do not fit together. In transitional periods, during hot water preparation and on sunny days, part of the energy can be used directly.

Additional energy storage and an energy management system can help shift consumption from evening hours to periods of higher PV production. System manufacturers point to the integration of pump, photovoltaics, and energy management as a way to increase the utilization of their own production.

Is it possible to get a subsidy for a heat pump in 2026?

Yes. The availability of the program depends primarily on whether we are dealing with a new or existing building.

For new houses, there is a "My Heat" program. In the case of an air pump, you can receive up to PLN 7000, and a ground pump – up to PLN 21,000. The subsidy is up to 30% of eligible costs or up to 45% in the case of Large Family Card holders. The call for applications lasts until December 31, 2026 or until the budget is exhausted.

In existing buildings, the pump can be financed under the "Clean Air" program. In the case of devices covered by the subsidy, it is important that they are on the ZUM list on the date of issuing the invoice. The program provides for different levels of support depending, among other things, on income and the scope of the project.

Advantages of a heat pump

Low power consumption in a well-chosen system

The pump does not convert all the electricity directly into heat, but uses it primarily to transport the energy taken from the environment.

This allows it to deliver several kilowatt hours of heat from one kilowatt hour of electricity.

No fuel burning at home

There is no need to store coal, pellets, or fuel oil. There is also no local combustion process in the building.

Heating and hot water in one system

An air-to-water or ground pump can handle both central heating and domestic hot water preparation.

Cooling capability

Some reversible devices can reverse the circulation and support the cooling of the building in the summer.

Cooperation with photovoltaics

The pump increases the electricity consumption of the home, so that part of the PV production can be used directly for heating or hot water preparation.

Automatic operation

Once the heating curve and automation are set correctly, daily operation can be reduced to a minimum.

Disadvantages of a heat pump

High initial cost

A complete investment is usually much more expensive than buying a traditional heat source alone. Ground pumps with vertical probes require particularly high investments.

Efficiency depends on the building

A pump installed in a poorly insulated house with a high-temperature installation can have a much higher energy consumption than a device working with underfloor heating in a well-insulated building.

Therefore, in the "Clean Air" program, not only the quality of the device is important, but also its correct selection to the needs of the building.

Air pump operates under changing conditions

The lower the outside air temperature and the higher the water temperature the installation requires, the harsh the operating conditions of the device.

This does not mean that the pump stops working in frost. On the other hand, it does mean that its effectiveness cannot be assessed solely on the basis of one catalogue COP.

Outdoor unit generates sound

The fan and compressor work during heating, so the installation site should take into account both the comfort of the inhabitants and the surroundings of the house.

Dependence on electricity

Without electrical power, the pump does not work. You can reduce the effects of power outages by designing a system with adequate backup power, but this requires additional infrastructure.

Frequently Asked Questions About Heat Pumps

Is a heat pump suitable for an old house?

Yes, but its installation should be preceded by an audit or at least a thorough analysis of the building's heat demand. An older house does not exclude a heat pump. However, the problem may be a large heat loss and an installation that requires very high water temperature. Sometimes it is more profitable to first insulate the building, replace some radiators or carry out other thermal modernization works.

Do you need underfloor heating for a heat pump?

No. The pump can also work with radiators. However, the supply temperature is crucial. The lower the temperature the installation needs to heat the house, the more favorable the pump's operating conditions. Therefore, underfloor heating is a very good partner for a heat pump, but it is not a prerequisite for its use.

Does a heat pump work in severe frost?

Yes, if the device is designed to work in such conditions. However, as the outside temperature drops, its power and efficiency change. Therefore, when choosing, you need to look at the parameters of the device for the temperatures occurring in a given climate zone, and not only at the power declared in mild weather.

How much electricity does a heat pump use per year?

There is no single value for all houses. For example, a building that needs 12,000 kWh of heat with a seasonal SCOP of 4 will consume about 3000 kWh of electricity. A house that requires 24,000 kWh of heat with a SCOP of 3 will already consume about 8000 kWh. Therefore, the calculation should be done for a specific building.

Which is better – a split or monoblock heat pump?

There is no universally better solution. In a monoblock, the refrigeration system is factory-enclosed in one unit. A split unit has an indoor and outdoor unit connected by working medium pipes. The type of construction itself does not determine efficiency – the parameters of a particular device, design and installation conditions are more important.

Which heat pump will be right for your home?

Choosing a pump should not start with the question: "8 or 10 kW?". First, you need to check the building itself.

The area, insulation, type of heating, number of inhabitants, demand for hot water, connection power and the planned connection of the pump with photovoltaics or energy storage are important.

Hymon Role

Hymon Powered by Kajima helps to choose a solution for the specific technical conditions of the house – both in new buildings and when modernizing existing heating. The analysis can also take into account the subsidy programs available in 2026.

Check what heat pump suits your home and how much it may cost to operate.

Choose a heat pump for your home.

The information presents the situation as at 31 August 2026. Prices of equipment, energy and the conditions of subsidy programs may change. The actual cost of investment and operation should be determined individually on the basis of the parameters of the building and the selected system.

Are you interested?

Contact us!